# EndoArt® Touch

> Fixed 06 Taper Precision

- **Manufacturer:** İnci Dental (Turkey)
- **Motion:** Continuous Rotation
- **Alloy:** Gold/Blue Heat-Treated NiTi
- **Key feature:** Fixed 06 taper system available in Gold and Blue heat treatment lines for predictable shaping

## Specifications

### Touch Gold

| File | Tip (mm) | Taper | Length | Cross-section | Motion | Speed (rpm) | Torque | Role |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| 10/06 | 0.10 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.0 Ncm | — |
| 15/06 | 0.15 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.2 Ncm | — |
| 20/06 | 0.20 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.5 Ncm | — |
| 25/06 | 0.25 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.5 Ncm | — |
| 30/06 | 0.30 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.5 Ncm | — |
| 35/06 | 0.35 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.5 Ncm | — |
| 40/06 | 0.40 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.5 Ncm | — |
| 45/06 | 0.45 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.5 Ncm | — |
| 50/06 | 0.50 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.5 Ncm | (optional) |

### Touch Blue

| File | Tip (mm) | Taper | Length | Cross-section | Motion | Speed (rpm) | Torque | Role |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| 10/06 | 0.10 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 1.5 Ncm | — |
| 15/06 | 0.15 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 1.5 Ncm | — |
| 20/06 | 0.20 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.5 Ncm | — |
| 25/06 | 0.25 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.5 Ncm | — |
| 30/06 | 0.30 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.5 Ncm | — |
| 35/06 | 0.35 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.5 Ncm | — |
| 40/06 | 0.40 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.5 Ncm | — |
| 45/06 | 0.45 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.5 Ncm | — |
| 50/06 | 0.50 | 6% | 21mm, 25mm, 31mm | Convex triangular | Continuous Rotation | 300 | 2.5 Ncm | (optional) |

| File | Tip (mm) | Taper | Length | Cross-section | Motion | Speed (rpm) | Torque | Role |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Orifice Opener | 0.19 | 8% | 19mm | Convex triangular | Continuous Rotation | 300 | 3.5 Ncm | — |

## Protocol

### Glide Path

1. **Establish Glide Path** — Establish a glide path with hand files before rotary shaping. Use standard scouting and negotiation technique per your training.
   - Pre-curve file for curved canals
   - Confirm smooth, reproducible path before rotary use
2. **Orifice Opening** — Use Orifice Opener (19/08) to create coronal access and improve straight-line access to the canal. _(File: Orifice Opener (19/08) · 300 RPM · 3.5 Ncm)_
   - Creates space for subsequent files

### Shaping

1. **Initial Shaping** — Select starting file based on canal anatomy. Available sizes: 10/06 through 50/06 in both Gold and Blue heat treatments. _(File: Touch Gold or Blue (06 taper) · 300 RPM · Gold: 2.0-2.2 Ncm / Blue: 1.5 Ncm (10/06-15/06))_
   - Minimal apical pressure — let file do the work
   - Clean flutes frequently, irrigate between files
2. **Progressive Shaping** — Progress through file sizes (20/06, 25/06, 30/06) until desired apical preparation is achieved. _(File: 20/06 → 25/06 → 30/06 · 300 RPM · 2.5 Ncm (Gold & Blue))_
   - Fixed 6% taper provides consistent preparation
   - Gauge with corresponding hand file after each size

### Finishing

1. **Apical Finishing** — Continue with larger sizes if needed. Verify apical preparation with corresponding hand file. _(File: 35/06 or 40/06 (if needed) · 300 RPM · 2.5 Ncm (Gold & Blue))_
   - Use larger sizes only if previous file is loose at WL
   - Verify tug-back with master cone before obturation

## Clinical Tips

- Touch Gold: Premium 6% taper files with gold heat treatment offering exceptional flexibility, strength, and fatigue resistance with an innovative cutting design for smooth navigation
- Touch Blue: 6% taper files with blue heat treatment offering superior precision, controlled memory for pre-bending, and effective debris removal for optimal shaping
- Gold heat treatment: 2x cyclic fatigue resistance vs conventional NiTi (manufacturer data, not independently verified)
- Blue heat treatment: 4x cyclic fatigue resistance vs conventional NiTi (manufacturer data, not independently verified)
- Blue files can be pre-bent before canal entry due to controlled memory
- Fixed 6% taper provides predictable and consistent canal preparation
- Touch Gold torque: 300 RPM, 2.0 Ncm (10/06), 2.2 Ncm (15/06), 2.5 Ncm (20/06–50/06)
- Touch Blue torque: 300 RPM, 1.5 Ncm (10/06–15/06), 2.5 Ncm (20/06–50/06)
- Orifice Opener (19/08): 300 RPM, 3.5 Ncm
- Autoclavable box per product pages — reuse/sterilization protocol not established in catalog; contact manufacturer for reprocessing instructions

## Warnings

- Inspect for distortion or deformation before each use — discard if defective
- Reuse and sterilization protocol not established in publicly available catalog — verify with manufacturer

## Best for

- fixed 6% taper
- predictable preparation
- standard cases

## Technical profile

- **Category:** multi-file-rotary
- **Heat treatment:** Gold Heat-Treated — Gold or Blue heat treatment options available
- **Manufacturing method:** ground
- **Pre-bendable:** yes
- **Motor:** any-rotary
- **Glide path requirement:** optional
- **Canal suitability:** Curvature: mild, moderate; Canal size: narrow, normal, wide; Calcified canals: no; Retreatment: no; Conservative access: no
- **Content revision:** 2026-07-15

## FAQ

**What alloy is EndoArt Touch made from?**

EndoArt® Touch is manufactured from Gold/Blue Heat-Treated NiTi.

**How many files are in the EndoArt Touch sequence?**

The EndoArt® Touch system includes 19 files: Orifice Opener, 10/06, 15/06, 20/06, 25/06, 30/06, 35/06, 40/06, 45/06, 50/06, 10/06, 15/06, 20/06, 25/06, 30/06, 35/06, 40/06, 45/06, 50/06.

**What is the EndoArt Touch file sequence?**

EndoArt® Touch is used in this order: Orifice Opener → 10/06 → 15/06 → 20/06 → 25/06 → 30/06 → 35/06 → 40/06 → 45/06 → 50/06. Per-file speed, torque and technique are in the protocol section above.

**What motion type does EndoArt Touch use?**

EndoArt® Touch uses continuous rotation motion.

**What cases is EndoArt Touch best for?**

EndoArt® Touch is best suited for: fixed 6% taper, predictable preparation, standard cases.

**What speed and torque settings are recommended for EndoArt Touch?**

Recommended settings: 300 RPM and 3.5 / 2.0 / 2.2 / 2.5 / 1.5 Ncm across the file sequence (refer to official DFU for full per-file parameters).

## References

- [Manufacturer instructions for use (DFU/IFU)](https://endoart.com.tr/assets/front-face/catalog/endoart-katalog-en.pdf)

## Related

- [HTML page](https://endo-guide.app/system/endoart-touch)
- [Manufacturer hub: Inci Dental (Turkey) Systems](https://endo-guide.app/manufacturer/inci-dental)
- [Compare systems](https://endo-guide.app/compare)
- Other languages: [Türkçe](https://endo-guide.app/tr/system/endoart-touch.md) · [Español](https://endo-guide.app/es/sistema/endoart-touch.md)
- [llms.txt](https://endo-guide.app/llms.txt) · [EndoGuide (Markdown)](https://endo-guide.app/index.md)

---

_Educational reference for dental professionals. Always confirm settings against the official manufacturer instructions for use before clinical procedures._