Skip to content
Pediatric File Systems
Continuous Rotation
Kedo Dental (India)

Kedo-S Square

Alloy
CM-Wire
Heat Treatment
CM-Wire (Controlled Memory)
Length
12mm, 14mm, 16mm
Taper
Variable (4-8%)

File List

A1
#25 / Variable
Anterior teeth
P1
#30 / Variable
Posterior teeth

Protocol

1

1. Canal Assessment

Suitable for anterior primary teeth. Evaluate canal size with radiograph.

2

2. Glide Path

Create glide path with #10-15 K-file.

3

3. Single-File Shaping

Shape with a single file using A1 or P1. 300-350 RPM.

4

4. Irrigation

Clean with NaOCl, final rinse with EDTA.

Clinical Tips

  • Single-file system - fast procedure
  • Ideal for short-crown anterior teeth
  • Square cross-section provides more resistance

Warnings

  • For anterior teeth only
  • Do not advance beyond the apex

Clinical Notes

  • Single-file system
  • Short length (12-16mm) suitable for primary teeth
  • CM-Wire flexibility

References

  • Mohamed RH et al. BMC Oral Health. 2022