Reciproc®
Original single-file reciprocating concept with dedicated RECIPROC motor setting and three apical size options
AlaşımM-Wire NiTiEğe3Doğrulanma
Teknik Özellikler
Terim tanımları için simgelere dokunun
| Eğe | Uç | Koniklik | Hareket |
|---|---|---|---|
| R25 | 0.25 | 8% | Resiprokal |
| R40 | 0.40 | 6% | Resiprokal |
| R50 | 0.50 | 5% | Resiprokal |
Klinik İpuçları
R25 for most canals; R40 when ISO #20 reaches WL passively; R50 when ISO #30 reaches WL passively — size selection per radiograph + hand-file gauging (per 2023 IFU)
Short, controlled pecking with frequent irrigation generally improves control in narrow canals
Use conservative apical enlargement; upsize only after hand-file gauging
Single-file reciprocation can simplify workflow when glide path and WL control are maintained
Uyarılar
- Single use only - do not reprocess or reuse
- Use only designated reciprocating motor settings; never continuous rotation
- Contains nickel - avoid use in patients with known nickel hypersensitivity
- Inspect file before and during use; discard if unwound, bent, or otherwise deformed
- Do not force progression in abruptly curved or blocked canals; re-establish patency with hand files first
- Do not fully immerse in NaOCl — only working part in max 5% concentration (per IFU)
- In severe curvatures: use the instrument manually; do not use in abrupt apical curvature — use pre-curved hand files instead (per 2023 IFU)
- For extremely curved canals: use file for one canal only to reduce breakage risk (per IFU)
Dolum Teknikleri
Tek kon, sıcak vertikal, carrier-based ve lateral kompaksiyon
Protokol
01Kayma Yolu
02Şekillendirme
03Bitirme
İlgili Sistemler
VDW Sistemleri sistemleri
Üretici sayfası
VDW SistemleriDiğer resiprokal sistemler
Hareket kategorisi
Resiprokal HareketKarşılaştırmalar
RECIPROCvsBioRaCeRECIPROCvsE-Flex GoldRECIPROCvsEdgeEvolveRECIPROCvsEdgeFile X7RECIPROCvsEdgeGlidePathRECIPROCvsEdgeOne FireRECIPROCvsEdgeTaper PlatinumRECIPROCvsEndoArt ActionRECIPROCvsEndoArt ExpertRECIPROCvsEndoArt SmartRECIPROCvsEndoArt TouchRECIPROCvsEndoSequenceRECIPROCvsESXRECIPROCvsHyFlex CMRECIPROCvsHyFlex EDMRECIPROCvsHyFlex GPFRECIPROCvsiRaCeRECIPROCvsiRaCe PlusRECIPROCvsK3XFRECIPROCvsMtwoRECIPROCvsOne CurveRECIPROCvsOne FlareRECIPROCvsOne RECIRECIPROCvsOne ShapeRECIPROCvsPathFileRECIPROCvsProDesign LogicRECIPROCvsProGliderRECIPROCvsProTaper GoldRECIPROCvsProTaper NextRECIPROCvsProTaper UltimateRECIPROCvsR-MotionRECIPROCvsRACE EVORECIPROCvsReciproc BlueRECIPROCvsTF AdaptiveRECIPROCvsTraverseRECIPROCvsTruNatomyRECIPROCvs2ShapeRECIPROCvsVDW.ROTATERECIPROCvsVortex BlueRECIPROCvsWaveOne GoldRECIPROCvsXP-endo FinisherRECIPROCvsXP-endo RetreatmentRECIPROCvsXP-endo RiseRECIPROCvsXP-endo ShaperRECIPROCvsZenFlex
Alaşım bilgisi
M-WireKlinik rehberler
Hazırlayan:Uzm. Dt. Levent Yüksel