| File | Tip | Taper | Speed rpm | Torque Ncm | Role |
|---|---|---|---|---|---|
| Navigator NT | |||||
| Navigator NT 15/.01 | 0.15 | 1% | 500 | 2.5 | Glide path |
| CM K File | |||||
| CM K File 15/.02 | 0.15 | 2% | 500 | 2.5 | Glide path |
| CM K File 20/.02 | 0.20 | 2% | 500 | 2.5 | Glide path |
HyFlex GPF files use 500 RPM and up to 2.5 Ncm torque (per HyFlex family brochure and summary). Any continuous-rotation endodontic motor may be used.
The three-file sequence (Navigator NT 15/.01, CM K File 15/.02, CM K File 20/.02) establishes a smooth glide path from initial scouting to #20/.02.
CM K Files have controlled memory properties, allowing them to track canal anatomy closely without shape memory rebound.
The Navigator NT file is an NiTi file (not CM-Wire), while the two CM K Files use CM-Wire technology.
Reusable files; shape regenerates during autoclaving. Visual inspection after autoclaving serves as a discard indicator.
Available in 21 mm, 25 mm, and 31 mm lengths, as well as assorted packs.
Obturation Techniques
Single cone, warm vertical, carrier-based & lateral compaction
From Coltene Systems
Manufacturer page
Coltene SystemsOther continuous rotation systems
Motion category
Continuous RotationComparisons
Clinical guides
What alloy is HyFlex GPF made from?
Answer
HyFlex® GPF is manufactured from CM-Wire (Controlled Memory NiTi).
How many files are in the HyFlex GPF sequence?
Answer
The HyFlex® GPF system includes 3 files: Navigator NT 15/.
What is the HyFlex GPF file sequence?
Answer
HyFlex® GPF is used in this order: Navigator NT 15/.
What motion type does HyFlex GPF use?
Answer
HyFlex® GPF uses continuous rotation motion.
What cases is HyFlex GPF best for?
Answer
HyFlex® GPF is best suited for: mechanical glide path creation, integration with HyFlex CM/EDM shaping systems, curved canals requiring pre-bendable glide path files.
What speed and torque settings are recommended for HyFlex GPF?
Answer
Recommended settings: 500 RPM and 2.
Reviewed by
Uzm. Dt. Levent Yüksel
DDS · Endodontist
Endodontist — DDS, Hacettepe University; endodontics specialty training, Ankara University. 10+ years of clinical experience. Sole author and reviewer of EndoGuide content.
Citation formats for the manufacturer-verified specification data on this page.
AMA
Yüksel L. HyFlex GPF: sequence, speed and torque settings. EndoGuide. Updated: 2026-03-25. https://endo-guide.app/system/hyflex-gpf
BibTeX
@misc{endoguide-hyflex-gpf,
author = {Yüksel, Levent},
title = {HyFlex GPF: sequence, speed and torque settings},
howpublished = {\url{https://endo-guide.app/system/hyflex-gpf}},
year = {2026},
note = {EndoGuide. Updated: 2026-03-25}
}Independent educational resource. Product names and trademarks belong to their respective manufacturers, who neither sponsor nor endorse EndoGuide.